For municipal lighting projects, contractors, and infrastructure developers, understanding the technical requirements for lighting poles is important when evaluating suppliers, preparing tender documents, and conducting quality inspections.
This article explains the scope, classification, technical requirements, testing methods, inspection procedures, marking requirements, and model designation of steel lighting poles.

Scope
This standard applies to top-mounted and bracket-mounted lighting poles with a height not exceeding 20 meters. The poles are designed for installation perpendicular to the mounting surface.
Normative References
The following referenced standards and documents are essential for applying this standard.
For dated references, only the specified edition applies. For undated references, the latest edition, including all amendments, is applicable.
The normative references cover the following areas:
-
Steel plate specifications
-
Salt spray environmental testing
-
Sampling inspection procedures
-
Product warranty documentation
-
Mechanical impact protection
-
Radiographic nondestructive testing of pressure equipment
-
General technical requirements for lighting poles

Classification of Lighting Poles
Lighting poles can be classified according to their structural design, cross-sectional shape, number of brackets, and installation method.
Classification by Pole Profile
Based on the shape of the main pole, lighting poles are divided into three categories:
Stepped poles
Constant-diameter poles
Tapered poles
Classification by Cross-Sectional Shape
Based on the cross-sectional shape of the main pole, lighting poles can be classified as:
Circular poles
Regular polygonal poles
Classification by Number of Brackets
Lighting poles are categorized into four types based on the number of cantilever brackets:
Poles without brackets
Single-arm poles
Double-arm poles
Multi-arm poles
Classification by Installation Method
Based on their installation method, lighting poles are divided into:
Direct-buried poles
Flange-mounted poles
Selecting the appropriate pole configuration is an important part of street lighting system design. Pole height, bracket arrangement, and installation conditions should be considered together with the lighting layout.
For additional guidance, see our article on how to design solar street light pole height and spacing.
Technical Requirements and Test Methods
Impact Resistance of Lighting Poles
Lighting poles must meet the IK08 impact protection rating specified in GB/T 20138.
The impact resistance test evaluates whether a lighting pole can withstand mechanical impacts without excessive deformation.
Test conditions
The test specimen must extend at least 0.3 m above and below the maintenance access door.
During testing, the maintenance door must remain closed.
The test may be conducted using either a pendulum impact hammer or a vertically falling impact hammer. A total of five impacts must be applied.
The impact locations are selected according to the cross-sectional shape of the pole, such as circular or regular octagonal sections. The corresponding impact points are determined along the circumference or surfaces of the pole.
Acceptance criteria
After testing, the depth of any indentation must not exceed 3 mm.
The test results may also apply to similar products with smaller wall thicknesses, lower material strength, or smaller outside diameters, provided the applicable conditions are satisfied.
Because impact resistance depends on the pole’s cross-sectional characteristics, these principles also apply to lighting poles with other non-standard cross-sectional shapes.
Corrosion Resistance
Lighting poles installed outdoors are continuously exposed to environmental conditions that may accelerate corrosion.
Therefore, the external surfaces of lighting poles must provide excellent corrosion resistance.
The corrosion protection methods described below may be used. Alternative protective treatments are also acceptable if they provide superior corrosion resistance.

Inspection Requirements for Corrosion Protection Coatings
The quality of a lighting pole’s corrosion protection layer must be verified through appropriate inspection procedures.
Test panels may be used for corrosion resistance evaluation, provided they are made from the same material, belong to the same production batch, and undergo the same corrosion protection treatment as the lighting poles.
Coating Thickness Inspection
a) General coating thickness measurement
For standard protective coatings, thickness should be measured using a nondestructive coating thickness gauge.
b) Multilayer composite coatings
For lighting poles with multilayer protective coatings, coating thickness can be verified using either of the following methods:
-
Microscopic thickness measurement
-
Inspection reports provided by the supplier for each individual coating layer
Salt Spray Testing
Salt spray testing must be conducted according to GB/T 2423.17.
The required test duration depends on the corrosion protection method.
| Corrosion protection method | Required salt spray test duration |
|---|---|
| Hot-dip galvanizing | 48 hours |
| Hot-dip aluminizing | 48 hours |
| Painting | 48 hours |
| Powder coating | 48 hours |
| Other protective treatments | 480 hours |
Acceptance Criteria
After completion of the salt spray test, the base material of the test panel must show no signs of:
-
Material damage
-
Rust formation
-
Pitting corrosion
-
Other visible corrosion
Damage limited to the surface of the protective coating does not automatically constitute a failure, provided the underlying base material remains unaffected.

Inspection Rules
Product inspections are divided into two categories:
Factory inspections
Type tests
Factory Inspection
Factory inspections cover dimensional accuracy, tolerances, corrosion resistance, structural integrity, and grounding connections.
The dimensional and tolerance inspections include:
-
Nominal pole height
-
Maintenance access door dimensions
-
Flange plate dimensions
-
Cross-sectional dimensional tolerances of metal lighting poles
-
Pole wall thickness
Corrosion resistance inspection must follow Clause 5.8.3(a), which specifies coating thickness measurement.

5.2 Inspection Frequency and Sampling
The structure and grounding terminals of every lighting pole must be inspected individually.
Dimensions, tolerances, and corrosion resistance may be inspected through batch sampling.
Lighting poles manufactured using the same materials, production processes, equipment, and specifications are considered a single inspection batch.
Sampling must follow GB/T 2828.4, with the following parameters:
| Parameter | Requirement |
|---|---|
| Sampling standard | GB/T 2828.4 |
| LQR level | 0 |
| DQL | 1.0 |
| Sampling plan | (5, 0) |
Under the specified (5, 0) sampling plan, five samples are inspected, and no nonconforming samples are permitted.
Type Testing
Type testing is required under any of the following circumstances:
When a new product design is finalized.
When production resumes after being suspended for more than one year.
When significant changes in design, production processes, or materials may affect product performance.
When factory inspection results differ significantly from the results of the previous type test.
When a regulatory or supervisory authority requests equipment conformity testing.
Test sample requirements
One complete lighting pole sample, together with the corresponding material test specimens, must be provided for type testing.
Handling nonconformities
If any item fails during type testing, the product must be adjusted or corrected.
The failed item and any related test items must then be tested again.
Type testing is considered successful only when all required test items meet the applicable standard.
For project buyers, these inspection requirements provide a basis for evaluating pole quality before shipment. Our guide on how to identify the quality of solar street lights and poles provides additional guidance for supplier evaluation and procurement.
Marking and Instructions for Use
Product Marking
All lighting poles and cantilever brackets must carry appropriate product identification.
At a minimum, the marking must include:
-
Manufacturer’s name or trademark
-
Product name
-
Product model
-
Production serial number
-
Reference to the applicable part of the standard
These markings enable product identification and traceability during procurement, installation, inspection, and maintenance.
Instructions for Use
Manufacturers must provide instructions containing the following information.
Structural and dimensional information
Structural drawings and dimensional diagrams of the lighting pole and its components.
Load-bearing limitations
The instructions must specify:
-
Maximum allowable wind speed
-
Maximum projected wind-exposed area
-
Maximum allowable luminaire weight
Installation requirements
Documentation must describe the installation conditions, installation procedures, and foundation requirements.
Maintenance instructions
The manufacturer must specify the recommended maintenance intervals and the inspection or maintenance items to be completed.
Proper installation and maintenance are important for maintaining structural safety and extending the service life of street lighting systems.
For practical installation guidance, refer to our article on how to install solar street lights.
Model Designation Method

Lighting pole models are designated using a standardized naming system that identifies the pole’s structural configuration and key specifications.
For example:
GG-DY10-2
This designation represents a steel lighting pole with the following characteristics:
| Item | Description |
|---|---|
| Main pole profile | Constant-diameter pole |
| Cross-sectional shape | Circular |
| Nominal height | 10 m |
| Cantilever configuration | Double-arm |
| Material | Steel |
The model designation allows manufacturers, designers, and procurement personnel to identify the basic configuration of a lighting pole.

Frequently Asked Questions About Street Lighting Pole Standards
What is the maximum lighting pole height covered by this standard?
The standard applies to top-mounted and bracket-mounted lighting poles with heights not exceeding 20 meters, installed perpendicular to the mounting surface.
What types of lighting poles are covered by the classification system?
Lighting poles are classified by pole profile, cross-sectional shape, number of cantilever arms, and installation method. Common configurations include stepped, constant-diameter, and tapered poles, as well as single-arm and double-arm arrangements.
What impact resistance rating is required for lighting poles?
Lighting poles must meet the IK08 impact protection rating specified in GB/T 20138. During the prescribed test, five impacts are applied, and the resulting indentation depth must not exceed 3 mm.
How is the corrosion resistance of lighting poles tested?
Corrosion resistance is evaluated through coating thickness inspection and salt spray testing. Under the requirements described in this article, hot-dip galvanized, hot-dip aluminized, painted, and powder-coated samples must pass a 48-hour salt spray test, while samples using other protective treatments must pass a 480-hour test.
What is the difference between factory inspection and type testing?
Factory inspection verifies production quality, including dimensions, tolerances, corrosion protection, structural integrity, and grounding connections. Type testing evaluates product conformity when a new design is introduced, significant modifications occur, production resumes after a long interruption, or other specified conditions arise.
How many lighting poles must be inspected during factory inspection?
Every lighting pole must undergo structural and grounding terminal inspections. Dimensional, tolerance, and corrosion resistance checks may be conducted by batch sampling. The specified sampling plan is (5, 0), meaning five samples are inspected with zero nonconforming samples allowed.
What information should a lighting pole manufacturer provide?
Manufacturers must provide product identification, structural and dimensional drawings, allowable wind speed, maximum projected wind-exposed area, maximum luminaire weight, installation instructions, foundation requirements, and maintenance guidance.
Why are lighting pole standards important for municipal solar street lighting projects?
Lighting pole standards help project owners, EPC contractors, and procurement teams establish consistent requirements for structural strength, corrosion protection, product traceability, testing, and installation. These requirements support supplier comparisons and help reduce the risk of premature damage, installation problems, and maintenance issues.
Conclusion
Lighting pole standards establish essential requirements for the design, manufacture, testing, inspection, and identification of steel lighting poles.
For municipal authorities, solar lighting contractors, and infrastructure developers, several factors deserve particular attention: IK08 impact resistance, corrosion protection, dimensional tolerances, factory inspection procedures, type testing, and documented wind-load limitations.
Understanding these requirements makes it easier to evaluate lighting pole specifications, compare supplier documentation, and select appropriate products for outdoor lighting projects.
A reliable street lighting installation depends not only on luminaire performance but also on the structural quality, installation conditions, and long-term durability of its supporting poles.

Belinda Wang, founder and CEO of ClodeSun. ClodeSun has over 13 years of experience in producing solar and LED lighting, ensuring our designs are perfectly adapted to the market’s needs. ClodeSun is passionate about solar streetlights and loves sharing our knowledge with the world.