Different countries and regions follow different lighting standards. Standards such as ANSI/IES RP-8-18, CIE 140:2000, and BS EN 13201-3:2015 use different calculation methods for observer positioning, veiling luminance, and target contrast. These differences can significantly affect lighting simulation results.

This article explains the main road lighting calculation metrics, differences between international standards, road surface reflection parameters, and the capabilities of commonly used lighting design software.
Professional lighting calculation tools can optimize illumination performance on straight road sections according to various international standards. However, selecting the appropriate standard and understanding its calculation conditions are essential for producing accurate and reliable lighting designs.
Common International Road Lighting Standards and Their Evaluation Criteria
Several international standards are widely used for road lighting design, each emphasizing different aspects of lighting performance.
In North America, ANSI/IES RP-8-18 provides a comprehensive framework for evaluating road lighting quality.
The International Commission on Illumination (CIE) publishes CIE 140:2019 and CIE TN 007:2017, which focus on road luminance, uniformity, and mesopic vision.
In Europe, BS EN 13201-3:2015 includes additional human-centered lighting metrics, such as semi-cylindrical illuminance and surround illuminance.
Other regional standards include:
-
ABNT NBR 5101:2012: Used for road lighting design in Brazil.
-
AS/NZS 1158.3.1:2020: Applied to lighting design for roads and public spaces in Australia and New Zealand.
-
IES RP-18: A specialized standard for tunnel lighting in the United States.
The calculation metrics supported by these standards are compared in Figure 2.
Mesopic luminance, calculated according to CIE TN 007:2017, is particularly useful for representing how the human eye responds to low-light conditions at night.
Comparison of calculation metrics supported by international road lighting standards

Main Road Lighting Calculation Metrics
Understanding the following metrics helps designers evaluate illumination quality, driver visibility, pedestrian safety, and visual comfort.
Road Luminance and Illuminance
Average Luminance (Lavg)
Average luminance is measured in candela per square meter (cd/m²). It describes the average brightness of the road surface as perceived from the driver’s viewpoint.
It is an important indicator of how clearly drivers can see the road ahead.
Calculating average luminance requires consideration of several factors, including road surface reflection characteristics, viewing angles, and luminaire light distribution.
Average Illuminance (Eavg) and Minimum Illuminance (Emin)
Both average and minimum illuminance are measured in lux (lx).
Average illuminance represents the overall level of light reaching the road surface, while minimum illuminance indicates the lowest illumination level within the calculation area.
The ratio between average and minimum illuminance, Eavg/Emin, helps evaluate lighting uniformity, which influences visual comfort and road safety.
Veiling Luminance and Glare Evaluation
Veiling Luminance (Lv)
Veiling luminance is measured in cd/m² and represents additional luminance caused by light scattering inside the human eye when exposed to luminaires or other bright light sources.
This scattered light reduces visual clarity and makes objects more difficult to identify.
Excessive veiling luminance can increase visual strain and negatively affect driving safety.
Veiling Luminance Ratio (Lv/Lavg)
This ratio compares veiling luminance with the average road luminance.
It is one of the key parameters used to assess how effectively a road lighting system controls glare.
Threshold Increment (TI)
Threshold increment is expressed as a percentage (%) and indicates how much glare increases the contrast required for a driver to recognize an object against its background.
A higher TI value means greater glare interference and more difficulty identifying objects.
In CIE and BS EN standards, TI is commonly used instead of the Lv/Lavg ratio for glare evaluation.
Small Target Visibility and Mesopic Luminance
Small Target Visibility (STV)
STV measures how easily drivers can detect small objects on the road, such as rocks, animals, and other potential hazards.
The calculation considers target contrast, background luminance, and veiling luminance.
A higher STV value generally indicates better visibility of small objects.
Mesopic Luminance (Lmes)
Mesopic luminance is measured in cd/m² and combines two types of human visual responses:
-
Scotopic vision, primarily associated with rod cells in low-light conditions.
-
Photopic vision, primarily associated with cone cells under brighter lighting conditions.
By accounting for both visual responses, mesopic luminance provides a more realistic assessment of brightness perception in nighttime environments.
This is particularly relevant for road lighting systems operating at relatively low illumination levels.
Illuminance Metrics for Pedestrians and Open Spaces
Vertical Illuminance (Ev)
Vertical illuminance is measured in lux and describes the amount of light reaching vertical surfaces, such as pedestrians’ faces or the front surfaces of vehicles.
It is commonly evaluated at a height of approximately 1.5 meters.
This metric helps assess pedestrian safety, facial recognition, and the ability to identify approaching people or vehicles.
Semi-Cylindrical Illuminance (Esc)
Semi-cylindrical illuminance is also measured in lux.
It evaluates the illumination received by an imaginary semi-cylindrical surface positioned at approximately chest height, typically 1.5 meters above the ground.
This calculation helps assess how well pedestrians are illuminated from different directions.
It is one of the human-centered lighting metrics recommended in European road lighting standards.
Hemispherical Illuminance (Ehs)
Hemispherical illuminance, measured in lux, describes the average illumination received by a virtual hemisphere from multiple directions.
The hemisphere is typically centered 1.5 meters above the ground.
This metric provides a broader evaluation of spatial lighting conditions and is useful for public squares, pedestrian walkways, and other open areas.
Task Area and Surrounding Illuminance
Surround Illuminance (EA)
Surround illuminance is measured in lux and refers to the average illumination in areas surrounding a defined visual task area.
These may include road edges, adjacent surfaces, or background areas.
The purpose of this metric is to evaluate the lighting balance between the main task area and its surroundings.
Appropriate surround illuminance can help reduce visual fatigue, improve spatial awareness, and create a greater sense of safety.
For solar-powered road lighting projects, these evaluation metrics should also be considered when determining luminaire output, mounting arrangements, and system capacity. Our guide to solar street light design calculations provides additional information on the design process.
Key Calculation Differences Between International Road Lighting Standards
Although international road lighting standards share many evaluation principles, they differ in observer positioning, glare calculations, and visibility assessment methods.
These differences can produce different simulation results even when the same luminaire and road geometry are used.
North American Standards: Observer Conditions and Target Visibility
ANSI/IES RP-8-18, together with the referenced tunnel lighting calculation provisions, uses specific observer conditions for road lighting evaluation.
The observer is positioned:
-
83.07 meters from the calculation point.
-
1.45 meters above the road surface.
-
With a viewing direction approximately 1 degree below the horizontal.
For veiling luminance calculations, the method does not apply line-of-sight (LOS) filtering and considers traffic traveling in one direction.
STV calculations include both positive-contrast and negative-contrast targets.
Positive contrast occurs when an object appears brighter than its background, while negative contrast occurs when the object appears darker.
By evaluating both situations, the standard provides a more comprehensive assessment of small-object visibility under different road lighting conditions.
CIE Standards and Mesopic Vision Calculations
CIE 140:2019 provides calculation methods applicable to CIE 115:2010.
Under these calculation conditions, the observer is positioned 60 meters from the reference point.
The observer may be located at the center of the traffic lane or at a position one-quarter of the road width from the road edge, depending on the calculation arrangement.
For veiling luminance calculations, the default method applies filtering to specified angular regions, including:
-
The central visual field between 0.1° and 1.5°.
-
Areas more than 60° away from the line of sight.
Glare is evaluated using Threshold Increment (TI), expressed as a percentage.
TI indicates how much glare increases the contrast threshold required to recognize an object.
Mesopic Calculations Under CIE TN 007:2017
CIE TN 007:2017 extends the calculation framework by incorporating mesopic luminance.
The method uses the formulas established in CIE 191:2010 and adjusts the visual adaptation level according to the actual average luminance.
This allows the calculation to account for changes in human visual sensitivity under nighttime lighting conditions.
European and Brazilian Standards
BS EN 13201-3:2015
The European standard incorporates additional illumination metrics, including:
-
Vertical illuminance
-
Semi-cylindrical illuminance
-
Hemispherical illuminance
These metrics help evaluate visibility from different directions, particularly for pedestrians and other road users.
Observer positioning generally follows the CIE calculation framework.
However, veiling luminance calculations do not filter out light sources along the line of sight by default.
Glare calculations also incorporate the methodology described in CIE 146:2002, with options allowing users to manually determine whether luminaires within the line of sight should be filtered.
ABNT NBR 5101:2012
The Brazilian standard follows calculation methods broadly similar to those used by CIE.
However, it places greater emphasis on semi-cylindrical illuminance, particularly for improving visibility and interaction between pedestrians and drivers.
Its calculations for veiling luminance and threshold increment are similar to the methods used in BS EN standards.
How Road Surface Reflection Affects Lighting Calculations
Road surface reflection is an important factor in road lighting design.
The road lighting calculation metrics discussed above generally exclude the influence of daylight. However, some standards account for changes in road surface conditions caused by wet weather.
Dry and wet roads have different reflective properties, which can influence calculated road luminance, lighting distribution, and energy efficiency.
Different road surface materials also reflect light differently.
To represent these characteristics, the lighting industry uses standardized road reflection tables, commonly called R-Tables.
These tables describe the reflection characteristics of different road surfaces and are used in road luminance calculations.
Road surface reflection table types and their average luminance coefficients

Understanding the Q0 Reflection Parameter
One of the most important parameters in an R-Table is Q0, the average luminance coefficient of the road surface.
The relationship between Q0 and the overall reflection coefficient can be expressed as:
A higher Q0 value indicates greater overall light-reflecting capability.
As a result, selecting the appropriate Q0 value can directly affect calculated road luminance levels and the apparent brightness distribution.
This parameter should therefore be carefully considered when evaluating road surface luminance and optimizing lighting efficiency.
For solar street lighting applications, accurate road reflection data can also help avoid unnecessary overdesign. Designers can select suitable lighting output and installation arrangements without relying solely on higher wattage.
For additional practical guidance, see our article on how to design solar street light pole height and spacing.
Lighting Design Software and International Standard Compatibility
Road lighting calculations can be performed using specialized lighting design software.
However, different programs support different standards, calculation methods, and standard editions.
Selecting the right tool depends on the project location, regulatory requirements, and the lighting performance metrics that must be evaluated.
DIALux evo
DIALux evo supports European road lighting standards, including BS EN 13201:2015 and earlier editions.
Its standard selection interface is shown in Figure 4.
Road lighting standard selection interface in DIALux evo

For European projects requiring calculations based on BS EN 13201-3:2015, DIALux evo is a suitable option.
Its capabilities make it useful for road lighting projects that must comply with European lighting design requirements.
DIALux 4.13
DIALux 4.13 supports older road lighting standards, including:
-
BS EN 13201:2004
-
IES RP-8-00
Its road lighting standard selection interface is shown in Figure 5.
Road lighting standard selection interface in DIALux 4.13

Although these options may be useful when reviewing older lighting designs, the standard editions are outdated.
Because DIALux 4.13 does not receive updates for newer road lighting standards, it is not recommended for projects requiring calculations under current standard editions.
AGi32
AGi32 supports a broad range of international road lighting standards and allows users to define custom calculation criteria.
Its road lighting standard selection interface is shown in Figure 6.
Standard selection interface in the AGi32 Roadway Lighting Optimizer

This flexibility makes AGi32 particularly useful for projects outside Europe, where different road lighting standards may apply.
However, calculation capabilities can vary between older and newer AGi32 versions.
Using an updated version is recommended when a project requires specific calculation metrics or more recent standard editions.
For North American road lighting projects, ANSI/IES RP-8-18 is an appropriate reference, and AGi32 is a recommended calculation tool.
Selecting Software for International Road Lighting Projects
The following table summarizes the software considerations discussed above.
| Project or requirement | Recommended software | Relevant standard |
|---|---|---|
| European road lighting projects | DIALux evo | BS EN 13201-3:2015 |
| North American road lighting projects | AGi32 | ANSI/IES RP-8-18 |
| Brazilian road lighting projects | AGi32 | ABNT NBR 5101:2012 |
| Australian and New Zealand projects | AGi32 | AS/NZS 1158.3.1:2020 |
| Reviewing older European designs | DIALux 4.13 | BS EN 13201:2004 |
| Projects requiring custom calculation criteria | AGi32 | Project-specific requirements |
Note: Software compatibility depends on the installed version and available calculation modules. Confirm the supported standards and editions before submitting project calculations.
For government tenders, municipal street lighting programs, and solar EPC projects, the specified lighting standard should be confirmed before selecting luminaires or preparing simulation reports.
This is especially important when developing a solar street lighting proposal for a government project, where lighting calculations, installation specifications, and compliance documentation may be required during technical evaluation.
Frequently Asked Questions About Road Lighting Design Standards
What are the main international standards for road lighting design?
Commonly used road lighting standards include ANSI/IES RP-8-18 in North America, CIE 140:2019 for road lighting calculations, and BS EN 13201-3:2015 in Europe.
Other regional standards include ABNT NBR 5101:2012 in Brazil and AS/NZS 1158.3.1:2020 in Australia and New Zealand.
The appropriate standard depends on the project’s location, road classification, and applicable technical requirements.
What is the difference between road luminance and illuminance?
Luminance measures the brightness of a road surface as perceived by an observer and is expressed in cd/m².
Illuminance measures the amount of light reaching a surface and is expressed in lux.
Luminance is particularly important for evaluating driver visibility, while illuminance is commonly used to assess overall lighting levels and uniformity.
What is Threshold Increment (TI) in road lighting?
Threshold Increment (TI) measures the effect of disability glare on an observer’s ability to recognize objects.
It is expressed as a percentage.
A higher TI value indicates that glare has increased the contrast required for object recognition, potentially reducing driving safety.
Why is small target visibility important for road safety?
Small Target Visibility (STV) evaluates how easily drivers can identify small objects on the roadway, such as stones, animals, or debris.
It considers target contrast, background luminance, and veiling luminance.
Improving STV can help drivers recognize potential hazards earlier.
How does road surface reflection affect lighting design?
Road surfaces reflect light differently depending on their material, texture, and moisture conditions.
Standardized R-Tables describe these reflection characteristics, while the Q0 parameter represents the average luminance coefficient.
Selecting the correct reflection data improves the accuracy of road luminance calculations and can help optimize lighting energy consumption.
Which software is better for road lighting design: DIALux or AGi32?
Both programs are used for professional lighting calculations.
DIALux evo is a suitable choice for European road lighting projects using BS EN 13201 standards.
AGi32 provides broad support for international standards and custom calculation criteria, making it useful for projects in North America and other international markets.
The best choice depends on the required standard, software version, and project specifications.
Can solar street lights meet international road lighting standards?
Yes. Solar street lighting systems can be designed to meet applicable road lighting performance requirements when their luminaires, optical distribution, mounting arrangements, and operating conditions are properly engineered.
However, compliance cannot be determined by wattage or lumen output alone.
Designers must evaluate the required luminance or illuminance, uniformity, glare control, and other applicable metrics. Solar systems must also provide sufficient battery capacity and energy autonomy to maintain the required lighting performance throughout the specified operating period.
What should be included in a road lighting calculation report for a government tender?
A road lighting calculation report should identify the applicable standard, road geometry, luminaire photometric data, mounting height, pole spacing, and observer conditions.
It should also present the required lighting performance metrics, such as average luminance, illuminance uniformity, and glare evaluation.
For solar street lighting projects, additional documentation may include solar panel capacity, battery capacity, operating schedules, autonomy calculations, and equipment specifications.
Tender-specific documentation requirements should always be checked before submission.
Conclusion
Effective road lighting design requires a clear understanding of lighting calculation metrics, observer conditions, road surface reflection characteristics, and the capabilities of different calculation software platforms.
Although international standards share many fundamental lighting principles, differences in observer positioning, glare assessment, and target visibility calculations can affect simulation results.
Choosing the appropriate standard is therefore essential for producing accurate and reliable lighting designs.
With its broad support for international standards, AGi32 provides a flexible platform for evaluating road lighting performance across different markets.
For lighting designers, municipal project teams, and solar EPC contractors, combining appropriate standards with accurate photometric calculations can improve road safety, visual comfort, and overall lighting system efficiency.

Belinda Wang, founder and CEO of ClodeSun. ClodeSun has over 13 years of experience in producing solar and LED lighting, ensuring our designs are perfectly adapted to the market’s needs. ClodeSun is passionate about solar streetlights and loves sharing our knowledge with the world.