LM-80 vs. TM-21 vs. LxxByy: How to Understand LED Lifespan and Lumen Maintenance

How long can an LED light last? The answer depends on more than the lifespan advertised by the manufacturer. To evaluate LED durability, buyers need to understand the test data, lifetime projections, and standardized performance ratings used in the lighting industry.

Three commonly used references are LM-80, TM-21, and LxxByy. Each serves a different purpose: LM-80 measures lumen maintenance under controlled conditions, TM-21 uses those measurements to project long-term performance, and LxxByy describes lumen maintenance performance and the proportion of LEDs that fall below a specified level.

LM-80 vs. TM-21 vs. LxxByy: How to Understand LED Lifespan and Lumen Maintenance
figure 1

Understanding these three concepts helps procurement teams, lighting contractors, and project developers interpret manufacturer reports and evaluate LED products for long-term installations.

Image: LM-80 and TM-21 Standard Documents

Image: LM-80 and TM-21 Standard Documents
figure 2

LM-80: Measuring LED Lumen Maintenance

LM-80 is a testing standard developed by the Illuminating Engineering Society (IES). It covers LED packages, modules, and arrays, measuring how their light output changes over time under different operating temperatures and drive currents.

The test results provide the foundation for predicting LED lumen depreciation. LM-80 reports are also commonly used in qualification and certification programs such as ENERGY STAR and the DesignLights Consortium (DLC) in North America.

How LM-80 Testing Works

During an LM-80 test, LED samples are operated under controlled conditions to measure their lumen maintenance over an extended period.

Testing generally involves three temperature conditions, commonly 55°C, 85°C, and a third temperature selected by the manufacturer, such as 105°C. A specified drive current is maintained throughout each test.

The minimum test duration is typically 6,000 hours, with measurements recorded at least every 1,000 hours. Extending the test to 10,000 hours provides additional data for more reliable lifetime projections.

The resulting report includes lumen maintenance curves at different temperatures, showing how the LEDs retain their initial light output over time.

Color stability is also evaluated by comparing the color difference between the initial measurement and the measurement after 6,000 hours. Sample quantities, color shift, and lumen depreciation may also need to satisfy the requirements of the relevant certification program.

What Does an LM-80 Report Tell You?

An LM-80 report shows how LED packages, modules, or arrays maintain their light output under specific testing conditions.

However, LM-80 does not directly establish the lifespan of a complete LED luminaire. It provides measured data for the tested LED components rather than predicting the lifetime of the entire lighting system.

To estimate long-term lumen maintenance beyond the testing period, LM-80 data must be evaluated using a projection method such as TM-21.

This distinction is especially important when evaluating international standards for high-quality solar street lights, where long-term LED performance is one of several factors affecting product quality.

Image: Lumen Maintenance and Lifetime Projection Curves at Different Temperatures

Image: Lumen Maintenance and Lifetime Projection Curves at Different Temperatures
figure 3

TM-21: Predicting LED Lifespan from Test Data

TM-21 is another method developed by the IES. It uses measured LM-80 data and mathematical models to project how LED light output may decrease over time.

While LM-80 provides actual test results, TM-21 extends those results to estimate long-term lumen maintenance under specified operating conditions.

TM-21 is particularly useful for evaluating the expected performance of LED packages and modules. Manufacturers can also use these projections during product development to assess how operating temperature and drive current may affect lumen maintenance.

How TM-21 Lifetime Projection Works

The process begins by normalizing the lumen maintenance data collected during LM-80 testing.

The initial luminous flux is set to 1, representing 100% of the original light output. The average normalized lumen maintenance value is then calculated for each measurement point under the relevant temperature and current conditions.

A sample quantity of around 20 LEDs is commonly recommended, and larger sample sizes can help improve the reliability of the projection.

A key principle of TM-21 is the limitation on the reported projection period.

The maximum reportable projection is generally six times the actual LM-80 test duration.

For example:

LM-80 test duration Maximum TM-21 reporting period
6,000 hours 36,000 hours
10,000 hours 60,000 hours

One of the most common outputs is the L70 lifetime, which represents the time at which an LED’s luminous flux is projected to decrease to 70% of its initial value.

Temperature is another important factor. TM-21 projections can account for operating conditions using temperature-dependent modeling, including approaches based on the Arrhenius relationship.

This allows manufacturers to evaluate lumen depreciation under different thermal conditions and use those findings to support LED product design.

Why TM-21 Matters for Lighting Projects

TM-21 is widely referenced in the lighting industry across North America, Europe, and Asia-Pacific. Its projections are also frequently included in technical documents submitted during project bidding.

For buyers, a TM-21 report provides a more meaningful basis for evaluating long-term lumen maintenance than an unsupported lifespan claim.

For example, when selecting LED luminaires for municipal road lighting, buyers should consider projected lumen depreciation together with thermal management, operating current, and installation conditions.

These factors also help explain why solar street lights gradually become dimmer after extended operation.

It is important to remember that TM-21 primarily projects LED component lumen maintenance. The complete luminaire’s service life also depends on drivers, electrical components, thermal management, and environmental exposure.

Image: TM-21 Input Data and Lifetime Projection Report Example

Image: TM-21 Input Data and Lifetime Projection Report Example
figure 4
Image: TM-21 Input Data and Lifetime Projection Report Example
figure 5

LxxByy: Describing LED Lumen Maintenance Over Time

LxxByy is a standardized way of expressing lumen maintenance performance for LED lighting products over a specified operating period.

It combines the expected lumen maintenance level with the proportion of LED products that fall below that level.

A typical specification may be written as:

L70 B10 @ 50,000 hours

This describes the percentage of initial luminous flux expected to be maintained after a specified number of operating hours, along with the proportion of the LED population that fails to meet that maintenance level.

What Does Lxx Mean?

Lxx represents a specified percentage of the initial luminous flux.

For example, L70 corresponds to 70% lumen maintenance. The L70 lifetime is the time at which luminous flux has declined to 70% of its initial value.

Other lumen maintenance levels can also be used, depending on the project’s performance requirements.

LM-80 vs. TM-21 vs. LxxByy: How to Understand LED Lifespan and Lumen Maintenance
figure 6

What Does Byy Mean?

Byy indicates the percentage of LEDs expected to fall below the specified lumen maintenance level.

For example, under an L70 condition, B10 means that 10% of the LED population is expected to fall below 70% lumen maintenance at the stated time.

Together, these two values help buyers understand both the expected light output and the proportion of products that may not meet the specified performance threshold.

How to Interpret L70 B10 @ 50,000 Hours

Consider an LED luminaire specified as L70 B10 @ 50,000 hours.

This indicates that after 50,000 operating hours, 90% of the relevant LED population is expected to maintain at least 70% of its initial luminous flux, while up to 10% may fall below that level.

This does not mean the luminaire automatically stops working after 50,000 hours. Instead, it describes a lumen maintenance performance threshold.

Such specifications are useful when comparing lighting products for municipal roads, sports facilities, industrial areas, and other large-scale installations where long-term light output matters.

For example, procurement officers evaluating municipal solar street lighting solutions can use lumen maintenance classifications to compare the expected long-term performance of different LED products.

However, LxxByy values should always be reviewed alongside the supporting test and projection documentation, rather than treated as a substitute for those reports.

LM-80 vs. TM-21 vs. LxxByy: Key Differences

Although these three references are closely related, they describe different aspects of LED lumen maintenance.

Item LM-80 TM-21 LxxByy
Primary purpose Measure lumen maintenance Project long-term lumen maintenance Express lumen maintenance and population performance
Basis Laboratory testing LM-80 test data and mathematical modeling Performance assessment at a specified operating time
Main output Measured lumen maintenance curves Projected lifetime, such as L70 Ratings such as L70 B10
Time consideration Actual testing duration Projection beyond test duration Specified operating period
Typical use LED component evaluation Lifetime prediction Product specifications and tender comparisons

These references are most useful when considered together.

LM-80 establishes how the LED components performed during testing. TM-21 uses the recorded data to project future lumen depreciation. LxxByy expresses the expected maintenance level and the proportion of products that may fall below it.

For major lighting projects, procurement teams should request the relevant documentation and confirm that the stated performance figures are supported by appropriate testing or assessment.

How to Evaluate LED Lifespan Before Purchasing

When reviewing LED lighting products, buyers should look beyond a single advertised lifespan figure.

An LED luminaire marketed with a lifetime of 50,000 or 100,000 hours does not necessarily deliver the same light output throughout that period.

A more useful evaluation examines the relationship between LM-80 test results, TM-21 lifetime projections, and the stated LxxByy performance.

Operating conditions must also be considered. High temperatures, unsuitable drive currents, and poor thermal management can accelerate lumen depreciation and affect long-term lighting performance.

For municipal projects, industrial facilities, and outdoor installations, long-term reliability also depends on components beyond the LED light source.

These include the LED driver, power supply, housing, protective components, and overall luminaire construction.

A complete evaluation therefore combines lumen maintenance data with the manufacturer’s product specifications and the actual operating conditions of the installation.

Frequently Asked Questions About LED Lifespan Standards

What is the difference between LM-80 and TM-21?

LM-80 measures the actual lumen maintenance of LED packages, modules, and arrays under controlled laboratory conditions. TM-21 uses LM-80 data and mathematical modeling to project how lumen output may change beyond the testing period. LM-80 provides measured results, while TM-21 provides a lifetime projection.

Does LM-80 testing determine the lifespan of an LED luminaire?

No. LM-80 measures lumen maintenance for LED packages, modules, or arrays, not the complete luminaire. The overall lifespan of a lighting fixture also depends on other components, including the driver, thermal management system, and power supply.

What does L70 mean in LED lighting?

L70 represents a lumen maintenance level of 70% of the initial luminous flux. An L70 lifetime indicates the operating time at which the LED is expected to produce 70% of its original light output. It does not necessarily indicate complete LED failure.

What does L70 B10 at 50,000 hours mean?

L70 B10 @ 50,000 hours indicates that after 50,000 operating hours, 90% of the relevant LED population is expected to maintain at least 70% of its initial luminous flux. The remaining 10% may fall below that level.

How long must an LED be tested under LM-80?

LM-80 testing commonly runs for at least 6,000 hours, with lumen maintenance measurements taken at intervals of no more than 1,000 hours. Testing for 10,000 hours provides additional data and allows a longer reportable TM-21 projection period.

Can TM-21 predict an LED lifespan of 100,000 hours?

TM-21 may mathematically estimate long-term lumen maintenance, but its reported projection is generally limited to six times the actual LM-80 testing period. Therefore, 10,000 hours of LM-80 testing supports a maximum TM-21 reported projection of 60,000 hours. A 100,000-hour claim requires careful examination of the supporting evidence and reporting method.

Why is LED operating temperature important for lifespan?

Higher operating temperatures can accelerate lumen depreciation and affect LED performance over time. LM-80 evaluates LEDs at different temperatures, while TM-21 uses the resulting data to support lifetime projections. Good thermal management helps maintain long-term light output.

Which LED lifespan documents should buyers request for a street lighting project?

Buyers should request the relevant LM-80 test report, TM-21 projection, and stated lumen maintenance rating, such as L70 B10 at a specified operating time. They should also review the complete luminaire specifications and confirm that the supporting evidence applies to the proposed product and operating conditions.

Conclusion

Evaluating LED lifespan requires understanding what each testing method or performance classification actually represents.

LM-80 provides measured lumen maintenance data, TM-21 projects long-term lumen depreciation, and LxxByy describes the expected maintenance level and the proportion of LEDs that may fall below it at a specified time.

Together, these references provide a clearer picture of long-term LED performance than a manufacturer’s advertised lifespan alone.

For lighting manufacturers, contractors, and procurement teams, reviewing all three helps support more informed product comparisons, technical evaluations, and purchasing decisions for long-term lighting projects.

clodesun

Belinda Wang, founder and CEO of ClodeSun. ClodeSun has over 13 years of experience in producing solar and LED lighting, ensuring our designs are perfectly adapted to the market’s needs. ClodeSun is passionate about solar streetlights and loves sharing our knowledge with the world.

Share: