LED Light Distribution Explained: IESNA Types I–V, Polar Curves, and Short, Medium, and Long Distributions

LED light distribution describes how light emitted by a luminaire spreads across an area, including its direction, intensity, and coverage. It plays an important role in lighting performance, energy efficiency, and visual comfort.

A well-designed light distribution provides adequate illuminance and uniformity while reducing energy consumption, glare, and light pollution. It also improves visibility and safety, creating a more comfortable lighting environment.

For LED lighting manufacturers, selecting the right optical design is essential to achieving the intended performance of a luminaire. For lighting engineers and designers, understanding different light distribution patterns helps them select suitable products for roads, parking lots, pedestrian pathways, and other outdoor applications.

This article explains how LED light distribution is measured and represented, introduces the IESNA Type I–V classification system, and compares short, medium, and long longitudinal distributions using practical DIALux evo simulations.

What Is LED Light Distribution?

Light emitted by an LED source does not always travel in the direction required for a particular lighting application. To direct light toward the intended area, manufacturers use optical components such as lenses and reflectors.

These components modify the spatial distribution of light, allowing a luminaire to produce a specific beam pattern.

The resulting light distribution is commonly represented by a Light Distribution Curve (LDC), also known as a photometric curve.

LED Light Distribution Explained: IESNA Types I–V, Polar Curves, and Short, Medium, and Long Distributions
FIgure 1

A luminous intensity distribution curve shows how the luminous intensity of a luminaire varies across different directions in space.

This curve is obtained through photometric measurements using specialized equipment, such as a goniophotometer.

The most common photometric file formats include:

  • IES (.ies): Widely used in North America.

  • LDT (.ldt): Commonly used in Europe.

Lighting buyers and project engineers can request these files directly from luminaire manufacturers to evaluate lighting performance before purchasing equipment.

Photometric curves are generally presented using two coordinate systems. Cartesian (rectangular) coordinates are often used for floodlights, while polar coordinates are commonly used for indoor lighting and road lighting applications.

How to Read LED Light Distribution Curves

LED Light Distribution Explained: IESNA Types I–V, Polar Curves, and Short, Medium, and Long Distributions
Figure 2

Polar Coordinate Light Distribution Curves

A polar light distribution curve represents the luminous intensity of a luminaire at different angles within a measurement plane passing through the light source’s center.

The measurement process begins by selecting a reference direction. The luminous intensity at each angle is measured and represented by a vector.

Connecting the endpoints of these vectors forms the polar light distribution curve, as illustrated on the left side of Figure 2.

This representation makes it easier to understand how light is distributed around a luminaire and is particularly useful for evaluating streetlights and general lighting fixtures.

Cartesian (Linear) Light Distribution Curves

Cartesian light distribution curves are commonly used for LED spotlights and floodlights.

These luminaires often concentrate their light within a relatively narrow solid angle. As a result, polar coordinates may not clearly display the details of their luminous intensity distribution.

Some manufacturers therefore use Cartesian coordinates to present the beam pattern.

In this representation:

  • The vertical axis indicates luminous intensity (I).

  • The horizontal axis indicates beam angle.

The right side of Figure 2 illustrates this type of light distribution curve.

Both representations describe the same fundamental characteristic: how the luminous intensity of a luminaire changes with direction.

IESNA Classification of Light Distribution Types

LED Light Distribution Explained: IESNA Types I–V, Polar Curves, and Short, Medium, and Long Distributions
Figure 3

The Illuminating Engineering Society of North America (IESNA), established in 1906, has played a major role in developing lighting standards and photometric classification systems.

Its light distribution classifications remain widely used in outdoor and roadway lighting design.

The luminaire distribution classification system was defined in ANSI/IESNA RP-8-1983. It provides standardized categories that describe how a luminaire distributes light across a given area.

These classifications help lighting professionals understand a fixture’s coverage pattern and evaluate its suitability for different applications.

The five commonly recognized lateral distribution types are:

  • Type I

  • Type II

  • Type III

  • Type IV

  • Type V

Longitudinal distributions are also described using classifications such as S (Short), M (Medium), and L (Long).

The classification considers the locations of points corresponding to 50% of maximum luminous intensity and the maximum luminous intensity itself.

These concepts are explained in more detail in the following sections.

Common Photometric File Standards

Several standardized photometric file formats are used in the lighting industry, including EULUMDAT, CIE 102, and IESNA LM-63.

IESNA LM-63 is widely used in North America, EULUMDAT is common in Europe, and CIE 102 has also been used in New Zealand.

ANSI/IESNA LM-63-2002 was approved by the American National Standards Institute (ANSI) and became a widely recognized photometric data format in North America, using the .ies file extension.

These files allow lighting designers to import manufacturers’ photometric data into lighting simulation software and evaluate the performance of different luminaires.

IESNA Lateral Light Distribution: Type I to Type V

IESNA lateral light distribution classifications describe how light spreads across the width of a road or illuminated area.

The classification is determined by the position of the 50% maximum luminous intensity trace relative to the luminaire.

In simple terms, lateral distribution indicates how effectively a streetlight directs illumination toward the house side and street side of its mounting position.

For example, Type I distribution may be appropriate for a narrow, single-lane road, while Type II may provide better coverage for a two-lane road.

However, these are general guidelines rather than fixed rules.

The actual coverage depends on installation parameters such as mounting height, tilt angle, bracket length, and the distance between the luminaire and the road edge.

IESNA defines five principal lateral distribution patterns, commonly used to select luminaires for roads and outdoor areas of different widths.

LED Light Distribution Explained: IESNA Types I–V, Polar Curves, and Short, Medium, and Long Distributions
Figure 4

In the IESNA classification diagram, the roadway is divided into five lateral zones based on multiples of mounting height (MH).

The distribution type is determined by the zone containing the 50% maximum luminous intensity trace.

For example, if the 50% intensity trace falls within the Type III zone, the luminaire is classified as Type III.

Based on the diagram, such a distribution may be suitable for a road approximately three lanes wide, depending on the installation conditions and required lighting performance.

Type I: Narrow Symmetrical or Asymmetrical Distribution

Range: 1 MH on the house side to 1 MH on the street side

Type I distribution occurs when the 50% maximum luminous intensity trace lies within one mounting height on either side of the luminaire’s position.

It produces a relatively narrow light distribution, which may be symmetrical or asymmetrical.

Typical applications include pedestrian walkways, narrow paths, and single-lane roads.

Type II: Narrow Asymmetrical Distribution

Range: 1–1.75 MH toward the street side

Type II distribution occurs when the 50% maximum luminous intensity trace lies between 1 and 1.75 times the mounting height on the street side.

It provides a narrow, asymmetrical distribution intended to direct light along roads without excessive spill beyond the required area.

Typical applications include one- or two-lane roads, arterial roads, and certain highway lighting installations.

Type III: Wide Asymmetrical Distribution

Range: 1.75–2.75 MH toward the street side

Type III distribution occurs when the 50% maximum luminous intensity trace lies between 1.75 and 2.75 times the mounting height on the street side.

Compared with Type II, it provides a wider lateral distribution, making it useful for illuminating broader roadway sections or open areas.

Typical applications include major roads, highways, and parking lots.

Type IV: Wide Asymmetrical Forward-Throw Distribution

Range: 2.75–3.75 MH toward the street side

Type IV distribution occurs when the 50% maximum luminous intensity trace lies between 2.75 and 3.75 times the mounting height on the street side.

This pattern directs much of the light forward, making it suitable for fixtures installed along the perimeter of an illuminated area.

Typical applications include parking lots, public squares, and wall-mounted area lighting.

Type V: Symmetrical Circular Distribution

Type V provides a circular, symmetrical light distribution around the luminaire.

Unlike Types II, III, and IV, which direct light predominantly toward one side, Type V distributes light more evenly around the fixture.

Typical applications include parking lots, open areas, and general outdoor area lighting.

Comparison of IESNA Lateral Distribution Types

Type Distribution pattern Typical applications
Type I Narrow symmetrical or asymmetrical Walkways, paths, single-lane roads
Type II Narrow asymmetrical 1–2 lane roads, arterial roads
Type III Wide asymmetrical Wide roads, highways, parking lots
Type IV Wide forward-throw asymmetrical Parking areas, squares, perimeter lighting
Type V Circular symmetrical Open areas, parking lots, general area lighting
LED Light Distribution Explained: IESNA Types I–V, Polar Curves, and Short, Medium, and Long Distributions
Figure 5

Comparison of Type II and Type III light distributions simulated using the DIALux evo road lighting module.

For municipal and commercial projects, the correct distribution type should be selected based on the actual road geometry and required lighting performance rather than road width alone.

For additional guidance on real-world installation parameters, refer to our article on how to design solar streetlight pole height and spacing.

Short, Medium, and Long Longitudinal Light Distribution

While lateral distribution describes how light spreads across the width of a roadway, longitudinal distribution describes how light extends along the road in both directions from the luminaire.

IESNA longitudinal light distribution classification is based on the position of the maximum luminous intensity, measured in candelas (cd), relative to the Transverse Roadway Line (TRL).

The roadway is divided into zones parallel to the TRL, with distances expressed as multiples of the luminaire mounting height (MH).

Longitudinal distribution is particularly important when determining the appropriate spacing between streetlight poles.

According to the IESNA classification guidelines:

  • Short (S): Generally associated with pole spacing below 2.25 times the mounting height.

  • Medium (M): Generally associated with pole spacing between 2.25 and 3.75 times the mounting height.

  • Long (L): Generally associated with pole spacing between 3.75 and 6.0 times the mounting height.

These categories provide useful guidance for preliminary lighting design, but they do not establish absolute pole-spacing limits.

Actual spacing depends on luminaire arrangement, road conditions, mounting height, and the required illuminance and uniformity.

In general, short longitudinal distributions suit relatively close pole spacing, while long distributions can help illuminate longer distances between poles.

LED Light Distribution Explained: IESNA Types I–V, Polar Curves, and Short, Medium, and Long Distributions
Figure 6

The IESNA longitudinal classification diagram divides the roadway into different zones according to the distance from the TRL.

The classification is determined by the zone containing the point of maximum luminous intensity (100%).

For example, if a streetlight’s maximum luminous intensity falls within the Medium zone, its longitudinal distribution is classified as Medium.

When combined with a Type II lateral distribution, the resulting classification is Type II Medium.

From the diagram, we can estimate that this type of luminaire may support pole spacing approximately 3.0–3.5 times its mounting height.

Five Longitudinal Distribution Categories

Classification Distance range Description
VS – Very Short 0–1.0 MH Maximum intensity is concentrated close to the luminaire
S – Short 1.0–2.25 MH Suitable for relatively short longitudinal coverage
M – Medium 2.25–3.75 MH Provides moderate longitudinal coverage
L – Long 3.75–6.0 MH Designed for longer longitudinal coverage
VL – Very Long Greater than 6.0 MH Maximum intensity extends beyond six times the mounting height

Very Short (VS): 0–1.0 MH

A longitudinal distribution is classified as Very Short when the maximum luminous intensity trace falls between 0 and 1.0 MH from the TRL.

Short (S): 1.0–2.25 MH

A Short longitudinal distribution occurs when the maximum luminous intensity trace falls between 1.0 and 2.25 MH.

Medium (M): 2.25–3.75 MH

A Medium longitudinal distribution occurs when the maximum luminous intensity trace falls between 2.25 and 3.75 MH.

Long (L): 3.75–6.0 MH

A Long longitudinal distribution occurs when the maximum luminous intensity trace falls between 3.75 and 6.0 MH.

Very Long (VL): Greater Than 6.0 MH

A Very Long longitudinal distribution occurs when the maximum luminous intensity trace falls beyond 6.0 MH.

These classifications help engineers understand how different luminaires distribute light along the roadway and support initial decisions about lighting pole spacing.

However, a luminaire with a longer distribution is not automatically more efficient or better suited to every roadway.

The final selection must consider lighting uniformity, glare, mounting conditions, and the project’s applicable lighting standard.

Practical Application: Type II Short vs. Type II Medium in DIALux evo

To understand how longitudinal light distribution affects actual streetlight installations, we can compare Type II Short (Type II S) and Type II Medium (Type II M) luminaires using DIALux evo.

The simulation uses the following roadway conditions:

Parameter Design condition
Road width 7 m
Number of lanes 3
Bracket outreach 0.8 m
Mounting height 8 m
Initial pole spacing 36 m
Lighting class EN 13201 M4
Software DIALux evo
Distribution patterns compared Type II S and Type II M

The photometric data for both luminaires were imported into DIALux evo to evaluate lighting performance under the same installation conditions.

Type II Short: Pole Spacing Reduced to 33 m

The simulation showed that the Type II S luminaire had a relatively short longitudinal distribution.

It could not distribute sufficient light toward the areas between adjacent streetlights when the pole spacing was set to 36 m.

As a result, the illumination at the midpoint between poles was insufficient to achieve the required uniformity.

To address this issue, the pole spacing had to be reduced from 36 m to 33 m.

This adjustment allowed the installation to provide more adequate illumination between the poles and satisfy the required uniformity.

Type II Medium: 36 m Pole Spacing Meets M4 Requirements

The Type II M luminaire performed better under the same roadway conditions.

Its medium longitudinal distribution allowed light to extend farther along both directions of the road.

At a pole spacing of 36 m, all simulated lighting parameters met the EN 13201 M4 requirements.

With an 8 m mounting height, the pole-spacing-to-mounting-height ratio was:

\[ \frac{36\text{ m}}{8\text{ m}}=4.5 \]

This means the poles were spaced 4.5 times the mounting height, slightly exceeding the 3.75 MH upper boundary commonly associated with the IESNA Medium category.

Nevertheless, the simulation confirmed that the Type II M luminaire met the required lighting performance.

This demonstrates why IESNA distribution categories should be used as preliminary design guidance rather than strict installation limits.

Simulation Results Comparison

Type II Short

33 m

Required pole spacing

Shorter coverage

Type II Medium

36 m

Acceptable pole spacing

Meets M4 requirements
Pole Spacing Comparison

Results reported in the source DIALux evo example. Both configurations were adjusted or selected to meet the required lighting uniformity.

The comparison shows that selecting a suitable longitudinal distribution can improve lighting coverage and potentially reduce the number of poles required along a roadway.

However, this result applies to the specific simulation conditions described above. Different luminaires, mounting heights, roadway widths, and lighting requirements may produce different results.

For solar streetlight projects, pole spacing should also be considered alongside solar panel capacity, battery sizing, and nighttime operating requirements. Our solar streetlight design and calculation guide explains additional factors involved in system design.

LED Light Distribution Explained: IESNA Types I–V, Polar Curves, and Short, Medium, and Long Distributions
Figure 7

DIALux evo simulation comparison of Type II Short and Type II Medium streetlights.

How to Select the Right Light Distribution for a Street Lighting Project

Understanding IESNA light distribution types makes it easier to identify suitable luminaires during the early stages of a lighting project.

For example, Type II lateral distribution may be suitable for one- or two-lane roads, while Type III may be more appropriate for wider roads and parking areas.

Longitudinal distribution provides additional guidance for pole spacing.

Short distributions are generally useful where poles are installed closer together, while Medium distributions can provide more coverage between poles.

In practical installations, Medium distributions may support pole spacing around four to five times the mounting height, depending on the actual photometric performance and site conditions.

These relationships are not universal rules.

Final selection should always be verified using DIALux evo or another suitable road lighting calculation program.

The following factors should be considered during luminaire selection:

  1. Road geometry: Road width, lane configuration, pedestrian areas, and surrounding obstacles.

  2. Mounting conditions: Pole height, pole spacing, bracket outreach, and luminaire tilt.

  3. Light distribution: Lateral and longitudinal distribution classifications.

  4. Lighting requirements: Average luminance or illuminance, uniformity, and glare limits.

  5. Photometric data: Manufacturer-provided IES or LDT files for accurate simulation.

  6. Project efficiency: The relationship between light distribution, pole quantity, installation cost, and energy consumption.

For municipal procurement projects, contractors should request verified photometric files and project-specific simulation reports from the lighting supplier rather than relying only on wattage, luminous flux, or beam angle.

A higher-wattage luminaire does not necessarily provide better road lighting if its light distribution is poorly matched to the installation conditions.

For more guidance on selecting products for public infrastructure, see our article on municipal solar streetlights.

Conclusion

LED light distribution is a fundamental part of effective roadway and outdoor lighting design.

The IESNA classification system provides a practical way to understand how luminaires distribute light laterally and longitudinally.

Type I through Type V describe different lateral coverage patterns, while Very Short, Short, Medium, Long, and Very Long classifications describe how far maximum luminous intensity extends along the roadway.

These classifications make preliminary luminaire selection easier, but they cannot replace project-specific lighting calculations.

The DIALux evo comparison demonstrates this clearly: under the given road conditions, a Type II Short luminaire required 33 m pole spacing, while a Type II Medium luminaire met the EN 13201 M4 requirements at 36 m.

Choosing the correct light distribution can help improve roadway uniformity, reduce unnecessary installations, and achieve better overall lighting performance.

For any road lighting project, the most reliable approach is to combine suitable photometric distribution data with simulation results and the applicable lighting standards.

Frequently Asked Questions About LED Light Distribution

What is LED light distribution?

LED light distribution describes how the luminous intensity of a luminaire is spread in different directions. It determines where the light reaches, how evenly an area is illuminated, and whether the fixture is suitable for a particular application. Manufacturers control light distribution using optical components such as lenses and reflectors.

What is the difference between Type II and Type III streetlight distribution?

Type II provides a relatively narrow asymmetrical distribution, commonly used for one- or two-lane roads. Type III offers wider lateral coverage and is often suitable for broader roadways, highways, and parking lots. The best choice depends on mounting height, road width, pole position, and photometric simulation results.

What is the difference between lateral and longitudinal light distribution?

Lateral distribution describes how light spreads across the width of a roadway, while longitudinal distribution describes how light extends along the road. IESNA Type I–V classifications describe lateral coverage, and Short, Medium, and Long classifications indicate longitudinal distribution characteristics.

What is the difference between Type II Short and Type II Medium?

Both luminaires have Type II lateral distributions, but they differ in longitudinal coverage. Type II Short concentrates its maximum intensity closer to the luminaire, while Type II Medium extends it farther along the road. In the example presented, Type II Short required 33 m pole spacing, whereas Type II Medium achieved the required performance at 36 m.

Does a longer light distribution mean streetlight poles can be spaced farther apart?

A longer longitudinal distribution may allow greater pole spacing, but it does not guarantee acceptable illumination. Pole spacing must still meet the applicable lighting requirements for luminance or illuminance, uniformity, and glare. Photometric simulations should confirm the spacing before installation.

What are IES and LDT files used for in street lighting design?

IES and LDT files contain photometric data describing how a luminaire distributes light. Lighting designers import these files into simulation software, such as DIALux evo, to calculate expected lighting performance before installation. Both formats help engineers compare luminaires and verify compliance with project requirements.

Which IESNA light distribution is best for parking lots?

Type III, Type IV, and Type V distributions are commonly used in parking lots. Type III provides relatively wide asymmetrical coverage, Type IV is useful near perimeter locations, and Type V provides symmetrical illumination around the fixture. The best distribution depends on the parking lot layout, pole positions, and illumination targets.

Can I select solar streetlights based only on wattage and lumens?

No. Wattage indicates electrical power consumption, and lumens indicate total luminous flux, but neither fully describes how light reaches the road surface. Solar streetlight selection should also consider photometric distribution, mounting height, uniformity, battery capacity, operating time, and the required lighting standard.

Author

Shao Wentao

Chief Technology Officer, DIALux China Independent Lighting Consultant Senior Lighting Designer and Lecturer

15 years of experience in the lighting industry, specializing in lighting applications across multiple fields and sharing practical knowledge with lighting professionals.

clodesun

Belinda Wang, founder and CEO of ClodeSun. ClodeSun has over 13 years of experience in producing solar and LED lighting, ensuring our designs are perfectly adapted to the market’s needs. ClodeSun is passionate about solar streetlights and loves sharing our knowledge with the world.

Share:

More Posts

Request For A Quote

Interested in finding the price, product specs, payment term and shipping for your next project?