When preparing photometric data for international lighting projects, manufacturers often need to provide both IES and LDT files. Both formats can be used for illuminance calculations, but they differ in the types of luminaire information they can store.
For file conversion, the LDT Editor allows users to convert IES files into LDT format, while Photometric Toolbox supports conversion in both directions.
Understanding the differences between these formats, as well as the capabilities and limitations of the available software, helps lighting manufacturers, engineers, and project contractors choose the right approach.
Basic Characteristics of IES and LDT Files
Photometric files describe how a light source distributes luminous intensity in different directions. Two commonly used ASCII-based formats are IES (.ies) and EULUMDAT (.ldt).
The IES format was developed by the Illuminating Engineering Society in North America and is supported by corresponding technical specifications.
EULUMDAT, commonly known as LDT, is widely used in the European lighting industry. However, unlike IES, EULUMDAT does not have an organization continuously maintaining its specifications. Its format has remained largely unchanged since 1990.
In the early development of lighting design software, IES files were primarily associated with AGi32 in North America, while LDT files were commonly used with DIALux and Relux in Europe.
As lighting software has evolved, both formats have become compatible with major lighting calculation programs, including DIALux, AGi32, and Relux. These programs may also support additional photometric file formats developed by other organizations.
How Is Photometric Data Measured?
The luminous intensity data stored in both IES and LDT files comes from laboratory measurements.
During photometric testing, the measurement system records luminous intensity at different angular positions around the light source. The measurement directions form a spherical distribution, with the detector oriented toward the center of the sphere.
Based on this measurement approach, light sources are treated as point sources when representing their angular luminous intensity distributions.
A schematic of the main structure of a goniophotometer is shown in Figure 1.
Main structure of a goniophotometer

For projects involving solar street lighting design calculations, accurate photometric data is important because it provides the light distribution information used to evaluate illuminance across roads and other outdoor areas.
What Information Can IES and LDT Files Store?
Although both formats contain luminous intensity distribution data, they differ in the additional information they can record.
Compared with IES, EULUMDAT can store more detailed luminaire information, including correlated color temperature (CCT), color rendering index (CRI), and information about multiple light sources.
An LDT file can therefore contain photometric information associated with different light source configurations and power ratings.
IES files primarily record the photometric and luminaire parameters required for lighting calculations. The main fields and luminous intensity data in an IES file are illustrated in Figure 2.
IES file structure and main data fields

LDT files contain more fields. Each line corresponds to specific information about the luminaire, light source, or photometric measurements.
A detailed explanation of the LDT file fields is provided in Figure 8 at the end of this article.
How IES and LDT Files Display Information in Lighting Software
The differences between these two formats can also be seen when importing files into lighting design software.
Importing an IES File into DIALux evo
When an IES file is imported into DIALux evo, the luminaire information page may display default values for parameters that are not provided in the file.
In the example shown in Figure 3, DIALux evo displays:
- Color temperature: 3000 K
- Color rendering index (CRI): 100
These are the default values displayed in the example, rather than necessarily the actual specifications of the luminaire.
Luminaire information displayed after importing an IES file into DIALux evo

Importing an LDT File with Additional Information
After converting the IES file into LDT format, the user can enter the luminaire’s color temperature and CRI.
DIALux can then display the values entered in the LDT file.
In the example shown in Figure 4, the luminaire information is set to:
- Color temperature: 4000 K
- Color rendering index (CRI): 80
Luminaire information displayed after adding color temperature and CRI to the LDT file

This difference is especially useful when manufacturers need to provide complete luminaire information to international customers.
For example, color temperature is an important specification when selecting solar street lights for different outdoor applications. Including the correct CCT and CRI information helps project designers review the luminaire specifications more accurately.
How to Convert IES to LDT Using LDT Editor
In the Chinese lighting market, photometric files are predominantly provided in IES format.
North American customers generally use IES files, while European customers more commonly request LDT files. This is one reason Chinese lighting exporters often need to prepare both formats.
Although goniophotometers can typically export IES and LDT files directly after testing, manufacturers may still need to convert existing photometric files.
What Is LDT Editor?
DIALux provides a free LDT Editor that allows users to view photometric files and modify certain data fields.
The software can open both IES and LDT files. However, it only offers LDT as a saving format.
This means that LDT Editor supports:
- IES to LDT conversion
- Opening and editing existing LDT files
It does not support exporting LDT files back into IES format.
For most applications requiring IES-to-LDT conversion, the free LDT Editor is sufficient.
Introduction to the official DIALux LDT Editor

Steps to Convert an IES File to LDT
The conversion process is straightforward:
- Open LDT Editor.
- Import the IES file you want to convert.
- Review the luminaire information and edit the necessary fields.
- Add or correct available specifications, such as color temperature and CRI.
- Save the file in LDT format.
The file editing interface is shown in Figure 6.
Luminaire information editing interface in LDT Editor

After saving, the resulting LDT file can be imported into compatible lighting calculation software.
How to Convert Between IES and LDT Using Photometric Toolbox
Photometric Toolbox, developed by the company behind AGi32, is a dedicated application for editing photometric files.
Compared with LDT Editor, it offers more extensive file processing capabilities.
One of its main advantages is that it supports conversion in both directions:
- IES to LDT
- LDT to IES
Converting IES to LDT
To convert an IES file into LDT format, open the IES file in Photometric Toolbox and use the Save As function to select LDT.
During the conversion, the software displays a dialog box requesting additional luminaire information.
Users can enter relevant specifications, including color temperature and color rendering index.
Once the required information has been entered, the file can be saved in LDT format.
Additional luminaire information dialog when exporting an LDT file in Photometric Toolbox

Converting LDT to IES
The reverse process follows a similar procedure.
Open the LDT file in Photometric Toolbox and save it in IES format.
This bidirectional capability makes the software suitable for manufacturers who regularly supply photometric data to customers in different markets.
The main limitation is its cost. Photometric Toolbox is a paid application, and its relatively high price may not be justified for users who only need occasional file conversion.
Other File Conversion Options
It is also possible to use certain Philips luminaire plugin programs to import and convert photometric files.
However, installing a complete plugin package solely for format conversion may be inconvenient.
Other commercial programs are available, but their applications are relatively specialized and are not discussed individually here.
Which IES and LDT Conversion Tool Should You Choose?
The most suitable conversion method depends on the direction of conversion, the frequency of use, and whether additional editing functions are required.
| Feature | DIALux LDT Editor | Photometric Toolbox |
|---|---|---|
| Open IES files | Yes | Yes |
| Open LDT files | Yes | Yes |
| Convert IES to LDT | Yes | Yes |
| Convert LDT to IES | No | Yes |
| Edit luminaire information | Yes, selected fields | Yes, more extensive functions |
| Cost | Free | Paid |
| Recommended use | Occasional IES-to-LDT conversion | Regular bidirectional conversion and photometric file editing |
For manufacturers who only need to deliver LDT files to European customers, the free LDT Editor is generally a practical option.
For manufacturers or lighting engineering teams that frequently exchange files between IES and LDT formats, Photometric Toolbox provides greater flexibility.
Regardless of the conversion method, users should confirm that the converted file retains the correct photometric data and that any additional luminaire specifications match the actual product.
This is particularly important when preparing documents for municipal lighting projects, EPC contractors, and international procurement.
The photometric file is only one part of the technical documentation needed for these applications. Contractors may also need to assess light output, pole spacing, mounting height, and other parameters when designing solar street light pole height and installation distance.
Frequently Asked Questions About IES and LDT Files
What is the main difference between IES and LDT files?
Both IES and LDT files store luminous intensity distribution data used for lighting calculations. The main difference is that LDT files can also contain additional luminaire information, such as color temperature, color rendering index, and information about multiple light sources.
Can DIALux evo open both IES and LDT files?
Yes. DIALux evo supports importing both IES and LDT photometric files. Both formats can be used in lighting calculations, although the amount of luminaire information displayed may differ.
How can I convert an IES file to LDT for free?
You can use the free LDT Editor provided by DIALux. Open the IES file, review or edit the available luminaire information, and save it in LDT format. The software cannot export files in the reverse direction.
Can an LDT file be converted into an IES file?
Yes. Photometric Toolbox supports converting LDT files into IES format. Open the LDT file and use the Save As function to export an IES file.
Why does DIALux show 3000 K and CRI 100 for an IES file?
In the example discussed in this article, DIALux evo displays 3000 K and CRI 100 as default values when the imported IES file does not provide the corresponding information. These displayed values should not automatically be treated as the actual specifications of the luminaire.
Do IES and LDT files produce the same illuminance calculation results?
Both formats can represent the luminous intensity distribution required for illuminance calculations. If the photometric data and relevant calculation parameters are preserved correctly during conversion, they should produce equivalent results under the same calculation conditions. Differences may occur if data or parameters are changed during conversion.
Which photometric file format should lighting manufacturers provide to international customers?
The appropriate format depends on the customer’s requirements and software. IES is commonly used in North America, while LDT is widely used in Europe. Manufacturers serving multiple markets may need to provide both formats.
Is Photometric Toolbox necessary for every IES and LDT conversion?
No. If you only need to convert IES files into LDT format, the free DIALux LDT Editor may be sufficient. Photometric Toolbox becomes more useful when you need bidirectional conversion or more extensive photometric file editing.
Conclusion
IES and LDT are both widely used photometric file formats for lighting design and illuminance calculations.
IES is commonly associated with North American lighting applications, while LDT is widely used in European lighting projects and can include additional luminaire information such as color temperature and CRI.
For straightforward IES-to-LDT conversion, DIALux’s free LDT Editor offers a convenient solution. When conversion is required in both directions, Photometric Toolbox provides broader functionality, although it requires a paid license.
For lighting manufacturers and exporters, preparing accurate files in the format requested by the customer helps streamline technical reviews, lighting calculations, and international project documentation.
Explanation of individual fields and line entries in an LDT file


Belinda Wang, founder and CEO of ClodeSun. ClodeSun has over 13 years of experience in producing solar and LED lighting, ensuring our designs are perfectly adapted to the market’s needs. ClodeSun is passionate about solar streetlights and loves sharing our knowledge with the world.