How to Read Light Distribution Curves: A Practical Guide to Photometric Charts and Beam Angles

Understanding light distribution curves is essential when selecting luminaires for roads, parks, residential areas, and commercial lighting projects. These charts show how light is distributed in different directions, helping lighting designers evaluate beam angles, luminous intensity, illumination coverage, and suitable installation arrangements.

 

Several common methods are used to represent light distribution. Each serves a different purpose, from showing the illuminated area beneath a spotlight to illustrating the directional intensity of a streetlight.

Common Methods of Representing Light Distribution

Conical Diagrams

Conical Diagram — Commonly Used for Ceiling Spotlights

Conical Diagram — Commonly Used for Ceiling Spotlights
Figure 1

Conical diagrams are generally used to illustrate the illumination produced by ceiling-mounted spotlights at different distances.

Take the first row of Figure 1 as an example:

  • Mounting distance (h): 1 meter

  • Light spot diameter (d): 25 cm

  • Average illuminance (Em): 16,160 lx

  • Maximum illuminance (Emax): 24,000 lx

The numerical values appear on the left, while the corresponding simulated light spots appear on the right.

All the necessary information is already provided in the diagram. Once you understand what each symbol represents, you can easily interpret the lighting results.

Equal-Angle Luminous Intensity Curves

Equal-Angle Luminous Intensity Curve — Circular Grid Diagram

Equal-Angle Luminous Intensity Curve — Circular Grid Diagram
Figure 2

Commonly Used for Streetlights

Commonly Used for Streetlights
Figure 3

Streetlights typically distribute light across a relatively wide area. Equal-angle luminous intensity diagrams are therefore often used to illustrate their light distribution.

These diagrams use curves of different colors to distinguish the indicated lighting levels, making the distribution easier to interpret visually.

Isolux Diagrams

Figure 4. Isolux Diagram — Commonly Used for Streetlights and Garden Lights

An isolux diagram shows how illuminance varies across an illuminated surface.

the red dot indicates the position of the luminaire.

the red dot indicates the position of the luminaire
Figure 4

The triangular marker indicates that the illuminance at a point 0.6 meters from the light is 50 lx.

Since streetlights are primarily designed to illuminate the ground, designers can use illuminance distribution diagrams directly when evaluating light control, without examining the light distribution in every other direction individually.

The diagrams discussed above make it relatively easy to read the relevant results. Lighting designers can obtain the information they need directly from these charts without performing additional calculations.

Understanding Polar Light Distribution Curves

Polar Light Distribution Curve

Polar Light Distribution Curve
Figure 5

To understand a polar light distribution curve, it helps to begin with the basic concept of polar coordinates.

In mathematics, a polar coordinate system is a two-dimensional coordinate system in which any point is defined by an angle and a distance from a fixed reference point called the origin or pole.

Polar Coordinates

Polar Coordinates
Figure 6

A polar coordinate system uses angles and concentric circles to locate points.

The angle indicates the direction, while the concentric circles indicate the distance from the origin.

Most luminaires direct light downward. For this reason, polar light distribution diagrams commonly use the vertically downward direction as the starting direction, designated 0°.

An Easy Way to Understand Polar Curves

The following example uses ants pulling on a rubber band to explain how a distribution curve is formed.

How to Read Light Distribution Curves: A Practical Guide to Photometric Charts and Beam Angles
Figure 7

Imagine several ants of different strengths pulling on a rubber band and moving in different directions.

Stronger ants travel farther, while weaker ants stop closer to the starting point.

How to Read Light Distribution Curves: A Practical Guide to Photometric Charts and Beam Angles
Figure 8

Now connect the positions where the ants stop.

How to Read Light Distribution Curves: A Practical Guide to Photometric Charts and Beam Angles
Figure 9

The resulting line represents the distribution of the ants’ pulling strength in different directions.

How to Read Light Distribution Curves: A Practical Guide to Photometric Charts and Beam Angles
Figure 10

From the diagram, we can see that the strength in the 0° direction is 3, while the strength at 30° is approximately 1.4.

Light can be represented in a similar way.

Instead of pulling strength, we use luminous intensity. By plotting the luminous intensity in each direction and connecting the points, we obtain a curve showing how the light’s intensity is distributed.

How to Read Light Distribution Curves: A Practical Guide to Photometric Charts and Beam Angles
Figure 11

This curve is called a luminous intensity distribution curve.

The ant example illustrates the relationship between direction and strength. Unlike ants, light does not stop at a particular point, but its luminous intensity can be measured in different directions.

In a polar diagram, the distance from the origin to the curve represents luminous intensity, while the angle indicates the direction of the light.

A curve describing this distribution is therefore known as a light distribution curve or luminous intensity distribution curve.

The following examples show how the curves differ between two types of luminaires.

Downlight Distribution Curves

For a downlight, the distribution curve is approximately circular, with the highest luminous intensity directly below the luminaire.

As the direction moves farther away from the vertical downward axis, luminous intensity decreases. Beyond 90°, no light is emitted in the illustrated distribution.

Polar Light Distribution Curve

Polar Light Distribution Curve
Figure 12

Common Representation Method for Indoor Luminaires

Common Representation Method for Indoor Luminaires
Figure 13

Spotlight Distribution Curves

Spotlights produce a much more concentrated beam.

Even a small angular deviation from the vertically downward direction causes luminous intensity to decrease rapidly. Beyond approximately 30°, very little light remains.

This means most of the light is concentrated within a relatively narrow angular range.

Polar Light Distribution Curve

Polar Light Distribution Curve
Figure 14

Common Representation Method for Indoor Luminaires

Common Representation Method for Indoor Luminaires
Figure 15

Cartesian Light Distribution Curves

When a polar distribution curve becomes extremely narrow, its details may be difficult to distinguish.

In such cases, a Cartesian coordinate system is often more useful.

Cartesian light distribution diagrams allow the spacing of the coordinate axes to be adjusted, making it possible to enlarge specific portions of a curve and examine finer details.

Cartesian Coordinates

Cartesian Coordinates
Figure 16

For this reason, narrow spotlight beams are frequently represented using Cartesian diagrams.

Cartesian Light Distribution Curve

Cartesian Light Distribution Curve
Figure 17

Commonly Used for Concentrated-Beam Luminaires

Commonly Used for Concentrated-Beam Luminaires
Figure 18

Polar diagrams provide an intuitive representation of light distribution in different directions, while Cartesian diagrams make it easier to enlarge and examine specific sections of the curve.

Both methods are useful when evaluating the optical performance of lighting products.

How to Read a Light Distribution Curve

How to Read a Light Distribution Curve

How to Read a Light Distribution Curve
Figure 19

A light distribution curve illustrates how a luminaire’s luminous intensity varies throughout space.

Understanding its shape and symmetry helps designers interpret the luminaire’s optical characteristics.

Three Types of Light Distribution Based on Symmetry

Light Distribution Curves Classified by Symmetry

Light Distribution Curves Classified by Symmetry
Figure 20

Based on their symmetry characteristics, light distribution curves can be divided into three categories:

  1. Axially symmetric distribution

  2. Symmetric distribution

  3. Asymmetric distribution

Axially Symmetric Distribution

Axially Symmetric Light Distribution

Axially Symmetric Light Distribution
Figure 21

Axial symmetry is also known as rotational symmetry.

For an axially symmetric luminaire, the light distribution is identical in every direction around its central axis.

Therefore, a single distribution curve is sufficient to describe its optical characteristics.

Symmetric Distribution

Symmetric Light Distribution

Symmetric Light Distribution
Figure 22

In a symmetric light distribution, the luminous intensity is not necessarily identical in every direction. However, the distribution remains symmetrical from front to back or from left to right.

Typically, two curves are used to represent the different planes:

  • A red or solid curve represents the 0°/180° plane.

  • A blue or dashed curve represents the 90°/270° plane.

In the example described here, the 90°/270° plane runs along the light source, while the 0°/180° plane is perpendicular to it.

Adjusting the luminaire’s tilt changes the direction in which the light source points. Rolling the luminaire sideways rotates it around the light source’s axis.

The following figure uses a linear fluorescent lamp to illustrate this type of distribution.

Light Distribution Curves of a Linear Fluorescent Lamp (Two Measurement Planes)

Light Distribution Curves of a Linear Fluorescent Lamp (Two Measurement Planes)
Figure 23

T — C0°–180°: Luminous intensity distribution in the plane perpendicular to the fluorescent tube.

A — C90°–270°: Luminous intensity distribution in the plane parallel to the fluorescent tube.

Asymmetric Distribution

Asymmetric light distribution does not maintain the same symmetry characteristics as the first two categories.

Different directions may have substantially different luminous intensity values and distribution patterns.

Understanding these differences is particularly useful when evaluating luminaires intended to illuminate specific areas or directions.

What Can Light Distribution Curves Tell Us?

Light distribution curves provide several types of useful optical information.

Evaluating Luminous Intensity

The magnitude and distribution of luminous intensity can be assessed directly from the curve without drawing an additional illustration.

In a polar light distribution diagram, the closer the curve is to the origin, the lower the luminous intensity in that direction.

Luminous Intensity Distribution Direction

Luminous Intensity Distribution Direction
Figure 24

Understanding Light Coverage and Projection

Light distribution curves also show the range and direction in which light is projected.

Evaluating Luminous Intensity Distribution

Evaluating Luminous Intensity Distribution
Figure 25

In the upper-left example, the streetlight distribution curve extends widely toward both sides, indicating that the light can cover a relatively large lateral range.

The lower-left example shows an elongated light distribution pattern, which is commonly used for wall-washing applications.

By comparing these distribution patterns, lighting designers can better understand how a luminaire directs light toward its intended target.

For solar roadway projects, this information is also relevant when determining the appropriate streetlight pole height and spacing.

Obtaining Optical Parameters and Calculating Illuminance

Obtaining Optical Parameter Information

Obtaining Optical Parameter Information
Figure 26

After reading the optical parameters from a light distribution curve, illuminance can be calculated using the point-by-point illuminance calculation method.

Calculating Illuminance from Luminous Intensity

Calculating Illuminance from Luminous Intensity
Figure 27

If the luminaire’s luminous flux and luminous intensity at a particular angle are known, the illuminance at a calculation point located x meters away in that direction can be determined.

This method helps lighting designers relate directional luminous intensity to the illumination received at a specific location.

How to Read the Beam Angle from a Light Distribution Curve

The beam angle is an important parameter when evaluating how concentrated or widely distributed a luminaire’s light output is.

The following procedure explains how to obtain the beam angle from a light distribution curve.

Step 1: Identify the Maximum Luminous Intensity

Step 1 — Find the Maximum Luminous Intensity

Step 1 — Find the Maximum Luminous Intensity
Figure 28

First, locate the highest luminous intensity value on the curve.

This value serves as the reference for determining the beam angle.

Step 2: Find Half of the Maximum Intensity

Step 2 — Determine Half of the Maximum Intensity and Locate It on the Curve

Step 2 — Determine Half of the Maximum Intensity and Locate It on the Curve
Figure 29

Calculate half of the maximum luminous intensity and identify where the distribution curve reaches that value.

Step 3: Read the Angle on One Side

Step 3 — Read the Angle at Half Maximum Intensity

Step 3 — Read the Angle at Half Maximum Intensity
Figure 30

At the half-intensity point, read the corresponding angle on one side of the curve.

This is the first angle needed to calculate the beam angle.

Step 4: Read the Angle on the Other Side

Step 4 — Read the Angle on the Opposite Side

Step 4 — Read the Angle on the Opposite Side
Figure 31

Repeat the same process on the opposite side of the distribution curve.

Step 5: Add the Two Angles

Step 5 — Add the Angles from Both Sides

Step 5 — Add the Angles from Both Sides
Figure 32

Add the two angular values to obtain the full beam angle.

The same reading method can be applied to Cartesian light distribution diagrams.

Reading the Beam Angle from a Cartesian Distribution Curve

Reading the Beam Angle from a Cartesian Distribution Curve
Figure 33

For the example shown:

\[ \text{Beam Angle}=60^\circ+55^\circ=115^\circ \]

Therefore, the full beam angle is 115°.

Beam Angle vs. Field Angle

Differences in Beam Angle Definitions

Differences in Beam Angle Definitions
Figure 34

An important consideration is whether the specified angle is measured at half of the maximum luminous intensity or at another percentage.

The original comparison distinguishes European CIE-based and American IES-based conventions.

Under the half-maximum-intensity method, the angle is determined at 50% of peak luminous intensity. The 10%-intensity method uses one-tenth of the maximum luminous intensity.

Since the 10% threshold is lower, the corresponding angular measurement is generally wider.

In Chinese lighting practice, the half-intensity definition is more commonly assumed by default.

When preparing international lighting specifications, however, it is important to distinguish between beam angle and field angle.

In common photometric terminology:

  • Beam angle (B50): The angle measured at 50% of the maximum luminous intensity.

  • Field angle (B10): The angle measured at 10% of the maximum luminous intensity.

A measurement standard or technical specification should clearly identify which definition is being used. A 10% field angle should not automatically be treated as a conventional 50% beam angle simply because the product is intended for the American market.

For solar streetlight procurement, clearly defined beam and field angles help buyers compare different luminaires on a consistent basis. Other factors affecting the selection of suitable luminaires are discussed in this guide to solar streetlight design calculations.

Using Distribution Curves to Evaluate Streetlight Coverage

What practical decisions can be made from these curves?

Using C0°–180° and C90°–270° Distribution Curves

Using C0°–180° and C90°–270° Distribution Curves
Figure 35

The figure highlights two important considerations.

C0°–180°:

  • Examine the maximum luminous intensity.

  • Determine how far the light extends toward both sides.

  • Use this information when evaluating the distance between lighting poles.

C90°–270°:

  • Examine the maximum luminous intensity.

  • Evaluate how far the light projects forward.

  • Use this information when considering the width of the road to be illuminated.

These directional characteristics help designers understand how a streetlight will distribute its light across a roadway.

American Streetlight Distribution Types

American lighting references also use distribution types to make streetlight patterns easier to recognize.

Streetlight Distribution Types

Streetlight Distribution Types
Figure 36

For example, the simplified illustration describes:

  • Type I: Light extends mainly toward the two sides, with little forward projection.

  • Type V: A rotationally symmetric distribution pattern.

This classification offers a convenient way to describe the general shape of a streetlight’s light distribution.

However, it also has limitations.

The five-type system divides light distribution into separate categories. When an actual distribution falls between two categories, the classification cannot describe every detail precisely.

It is therefore more suitable for qualitative comparisons than for detailed numerical analysis.

For engineering decisions, the complete photometric distribution and the resulting illuminance calculations remain important.

This is particularly relevant when comparing solar-powered LED streetlights with traditional high-pressure sodium streetlights, since different optical systems can produce different illumination patterns even when their overall light output is similar.

How Are Light Distribution Curves Obtained?

Light distribution curves are produced from actual photometric measurements rather than drawn arbitrarily.

Specialized instruments measure the luminous intensity emitted by a luminaire in different directions.

The measurement results are then used to create the distribution curves.

The following figures show four common types of photometric measurement equipment.

The people included in the images provide a visual reference for understanding the size of the instruments.

Moving-Mirror Goniophotometer

Moving-Mirror Goniophotometer

Moving-Mirror Goniophotometer
Figure 37

C-Type Goniophotometer for Large Luminaires

C-Type Goniophotometer for Large Luminaires

C-Type Goniophotometer for Large Luminaires
Figure 38

Integrated Distribution Photometer

Integrated Distribution Photometer

Integrated Distribution Photometer
Figure 39

Near-Field Goniophotometer

Near-Field Goniophotometer

Near-Field Goniophotometer
Figure 40

These instruments provide the measurement data needed to describe the directional light output of different luminaires.

Understanding how the curves are obtained also helps engineers and buyers recognize the value of measured photometric data when evaluating lighting products.

Why Light Distribution Curves Matter in Lighting Projects

A clear understanding of light distribution curves is fundamental to using luminaires effectively.

Conical diagrams help users evaluate spot size and illuminance at different distances. Isolux diagrams illustrate ground-level illumination. Polar light distribution curves provide an intuitive view of directional luminous intensity, while Cartesian diagrams make narrow beam patterns easier to examine.

By learning to interpret these diagrams, lighting designers, project engineers, and procurement teams can better understand luminous intensity, beam angles, illumination coverage, and luminaire placement.

For outdoor and solar street lighting projects, these skills help improve product comparisons and provide a sound basis for lighting design decisions.

Frequently Asked Questions About Light Distribution Curves

What is a light distribution curve?

A light distribution curve is a graphical representation of how a luminaire’s luminous intensity varies with direction. It helps lighting designers understand where the light is concentrated and how widely it spreads.

What is the difference between a polar and a Cartesian light distribution curve?

A polar diagram represents luminous intensity using angles and radial distances from an origin. It provides an intuitive view of the overall distribution pattern.

A Cartesian diagram plots luminous intensity against angle on perpendicular axes. It is particularly useful for examining narrow beams or small changes in luminous intensity.

How do you calculate the beam angle of an LED luminaire?

First, identify the maximum luminous intensity. Then find the angles on either side of the distribution where intensity falls to 50% of that maximum.

The angle between these two directions is the full beam angle.

For example, if the two angles are 60° and 55° on opposite sides of the reference direction, the beam angle is 115°.

What is the difference between beam angle and field angle?

Beam angle commonly refers to the angular width measured at 50% of peak luminous intensity (B50).

Field angle commonly refers to the width measured at 10% of peak luminous intensity (B10).

Since the field angle uses a lower intensity threshold, it is normally larger than the corresponding beam angle for the same luminaire.

Which light distribution diagram is most useful for streetlights?

Streetlight designers commonly use polar luminous intensity distribution curves and isolux diagrams.

Polar curves show how light is directed in different angular planes. Isolux diagrams show how illuminance is distributed over the road surface.

Together, they provide useful information about the luminaire’s optical performance.

Why are the C0°–180° and C90°–270° planes important?

These planes describe luminous intensity distribution in two different vertical sections through the luminaire.

For a linear light source, one plane may be perpendicular to the lamp axis while the other is parallel to it.

In streetlighting applications, examining different distribution planes helps designers understand the relationship between light projection, roadway coverage, and luminaire orientation.

Can a light distribution curve determine the correct spacing between solar streetlight poles?

A light distribution curve provides important information for pole-spacing calculations, but it is not sufficient on its own.

Designers also need to consider mounting height, roadway width, luminaire orientation, target illuminance, uniformity, and other project requirements.

The complete photometric data can then be used in lighting calculations to evaluate a suitable installation arrangement.

How are light distribution curves measured?

Light distribution curves are generated using photometric measurement equipment such as goniophotometers.

These instruments measure the luminous intensity emitted in different directions. The measured values are plotted to produce a graphical representation of the luminaire’s light distribution.

Such measurements help manufacturers and lighting designers evaluate optical performance and prepare photometric documentation.

clodesun

Belinda Wang, founder and CEO of ClodeSun. ClodeSun has over 13 years of experience in producing solar and LED lighting, ensuring our designs are perfectly adapted to the market’s needs. ClodeSun is passionate about solar streetlights and loves sharing our knowledge with the world.

Share:

More Posts

Request For A Quote

Interested in finding the price, product specs, payment term and shipping for your next project?